Reference quick start
Place Cuekeeping Reference last on your stereo mix bus. Keep your session and interface at 48 kHz. Load a reference into slot 1, 2 or 3, then use A for your mix and B for the selected reference. The reference follows your DAW's transport. Offset sets where reference time 0 begins on the DAW timeline.
Play the passage for at least 3 seconds and click Match. The default adjusts the reference toward your mix's loudness without changing your mix. A headroom limit means the reference can't reach that level within the scanned ceiling. Safe comparison permits shared listening attenuation on the next Match. Clear match restores both gains to 0.
Compare the same passage at a similar level. Solo a frequency band to hear where the balance changes, or switch to Mono and Sides to check the stereo picture. The spectrum can overlay mix and reference or display Mid/Side. Listening controls and analyzer views work independently.
Click the meter heading to choose the measured source. Meter readings are taken before matching and listening filters. Reset meters before a fresh pass, then play the whole cue for a whole-track reading. A data-gap warning means you need a new pass. Settings contains analyzer options, reference management and saved collections.
Keep copies a reference into Music/Cuekeeping References. Presets store links, not audio. If you move a source, use Relink. Save your DAW project to recall its own comparison settings.
Offline export returns the unchanged DAW mix. Before a real-time bounce or internal resampling, select A, Full and Stereo and click Clear match. Those recording methods capture what you're monitoring.